Skip to main content

GMP STANDARD. EU CE CERTIFIED.

Direct Room Ultrasonic Humidifiers

Introduce humidity directly into individual rooms and production zones with CleanSPOT direct-room ultrasonic humidifiers. Select capacities from 4–35 L/h, with wall or ceiling mounting and control options matched to your facility.

These units are designed for spaces where central HVAC humidification is unavailable or where separate rooms need local humidity control. Multiple units can operate in parallel when a project requires distributed capacity.

Eight capacities  |  Wall or ceiling mounting  |  Configuration-dependent ON/OFF and 0–10 V control

CleanSPOT direct-room ultrasonic humidifier installed in a production room

Wall and Ceiling Installation

Direct-room systems can be supplied with mounting equipment for wall or ceiling installation. An external water reservoir can also be connected using quick-connect fittings where required.

Share a room layout and proposed equipment position so the installation can be reviewed alongside airflow, access and humidity demand. If your project requires mist introduction into ventilation airflow, explore our duct and AHU humidifiers instead.

CleanSPOT direct-room ultrasonic humidifier, wall-mounted installation
Wall Mounting
CleanSPOT direct-room ultrasonic humidifier, ceiling-mounted installation
Ceiling Mounting

Choose Your G-Series Direct Room Humidifier

Select an initial capacity below, then have it checked against your operating conditions. The required output depends on temperature, target RH, ventilation and process loads as well as room volume. Confirm mounting, controls and water-management options with your quotation.

Model Nominal Output
CleanSPOT G-4S Direct-Room Ultrasonic Humidifier4 L/hRequest quote →
CleanSPOT G-5S Direct-Room Ultrasonic Humidifier5 L/hRequest quote →
CleanSPOT G-7S Direct-Room Ultrasonic Humidifier7 L/hRequest quote →
CleanSPOT G-10S Direct-Room Ultrasonic Humidifier10 L/hRequest quote →
CleanSPOT G-14S Direct-Room Ultrasonic Humidifier14 L/hRequest quote →
CleanSPOT G-21S Direct-Room Ultrasonic Humidifier21 L/hRequest quote →
CleanSPOT G-28S Direct-Room Ultrasonic Humidifier28 L/hRequest quote →
CleanSPOT G-35S Direct-Room Ultrasonic Humidifier35 L/hRequest quote →

Controls, Capacity and Water Management

Control Integration

Depending on configuration, an external humidity controller, humidistat, PLC or building-management system can control the humidifier through ON/OFF switching or a 0–10 V proportional signal. The analog input allows humidification output to follow demand from the external controller.

Distribute Capacity

Multiple direct-room humidifiers can be installed in parallel when more output or distributed humidification is required. Unit quantity and placement are selected for the actual moisture load and room arrangement.

Water Management & Service Access

Automatic filling, drainage and reservoir emptying can be incorporated, with dual water-level monitoring, dry-run and thermal protection. Programmable drain intervals can be set from 1–99 hours where included. A replaceable air filter supports routine maintenance. An integrated 265 nm UV-C LED provides an additional hygiene measure inside the water tank. It complements appropriate water treatment, cleaning and maintenance; it does not disinfect the room.

HOW IT WORKS

How Direct Room Humidification Works

Ultrasonic atomization

A high-frequency transducer vibrates water into a fine mist, no heating element, no steam.

Reverse osmosis water

RO water reduces mineral content, helping limit deposits in the humidifier.

Mist distribution

The generated mist is introduced directly into the room, for humidification within the areas served by the unit.
OUR PROCESS

How We Work

From initial plan to installed system, trained, and backed by a year of support.

01

Consultation & Plan

You send us a plan, or we visit your facility. Together we define the right humidification setup for your needs.
02

Ordering

Once confirmed, production begins. Standard lead time is 30 days for orders up to 100 units, larger orders may take longer.
03

Delivery & Installation

Systems are shipped to you directly, or our team installs on-site when needed. IQ/OQ documentation provided to support your compliance audits.
04

Training

Your team is trained on operation and maintenance after installation.
05

Technical Support

One year of technical support included with every system.
CleanSPOT installation and support process for direct-room humidifiers
INSTALLATION PROCESS
Built Around Your Facility
WHERE THESE UNITS ARE INSTALLED

Industries Served

PRICING

Indicative Pricing by Capacity

Indicative pricing per L/h of rated capacity. Final pricing is confirmed with our team based on your installation, control setup and order volume.

G-4S – G-10S
€99
per L/h of rated capacity
G-14S – G-21S
€95
per L/h of rated capacity
G-28S – G-35S
€85
per L/h of rated capacity

Pricing includes installation and control integration for your facility.

Get a firm quote
BUYING QUESTIONS

Frequently Asked Questions

How do I choose between the eight capacities? −
Start with the moisture demand, not floor area alone. Room volume, air changes, temperature, target RH and process conditions affect the required L/h. Share these details for model selection rather than assuming a fixed area coverage for each unit.
Can the humidifier be mounted on a ceiling? +
Yes. Direct-room systems can be supplied with mounting equipment for wall or ceiling installation. Confirm the selected arrangement and installation requirements with the quotation.
Can my existing controller operate the unit? +
Configuration-dependent control is available through ON/OFF or 0–10 V interfaces. Provide your controller details and required signal so compatibility can be reviewed.
Can several units humidify one large room? +
Yes. Multiple units can operate in parallel to increase and distribute capacity. Final selection considers the room's moisture load, layout and operating conditions, including how the units will be controlled.
How is pricing structured? +
Indicative pricing is per L/h of rated capacity. Pricing includes installation and control integration for your facility. Contact us for a firm quote based on your specific configuration.
Request Model Selection for Your Room

Send your room dimensions, temperature, current and required RH, ventilation information and available control signal. Include a layout or photos if available. CleanSPOT can help determine the output and configuration required for the project.

Request a direct-room quote